In many locations from chemistry laboratories to industrial amenities, so as to guarantee the security of life and property towards a possible hearth hazard, extinguishing methods are used in addition to detection and alarm systems. It is also extremely necessary that the extinguishing methods put in may be triggered by the fireplace extinguishing management panel, to be able to get rid of a possible fire with early intervention.
In order to meet these wants, and with 35 years of sectoral information and experience, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel operating according to the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the remote performance of the symptoms and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be began manually and remotely; and
to make certain that the extinguishing course of could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these devices are produced using surface-mount know-how and are aimed toward making the automation of the extinguishing system and hearth and gasoline detection system excellent.
Image copyright: Mavili
Mavili Elektronik develops its products by at all times contemplating the wants of the set up. In circumstances that require the integration of the extinguishing system with the intelligent addressable fire detection system, it provides solutions by way of the monitoring modules that even have a ‘supervised’ choice.
Supervised monitoring modules play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or quick circuit in the wiring between the contact monitoring modules and the peripheral methods could cause disruption of the triggering, with potentially critical consequences. For this purpose, when selecting monitoring modules, it should be taken into account that they have supervised options.
Image copyright: Mavili
Since Maxlogic clever addressable fire detection and alarm control panels are constantly speaking with ‘supervise’ contact monitoring modules linked to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch conditions such as open circuits and quick circuits that may occur in the system. Many duties could be performed within the fire extinguishing installation, such because the management and monitoring of all valves that may interrupt the flow of water, water move alarm switches, strain change, and electrical or diesel fire pumps.
By including nuova fima pressure gauge ราคา monitoring modules to 2 separate relay outputs positioned above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to manage errors and the opposite to control the fireplace situation, monitoring and control of the extinguishing system by way of an intelligent addressable fire detection and alarm system can be performed effectively.
For extra info, go to www.mavili.com.tr/en
Share